EXCLUSIVE FORUM FOR MACHINE DISMANTLERS AND REPAIR PEOPLE   >   Hammond   >   Agricultural and Construiction   >   Fertilizer Production and Distrobution   >   White-rodgers temperature control 2B61-430

White-rodgers temperature control 2B61-430


Provides Auxiliary Heater Lockout During Mild Weather
Dimensions . . . . . . . . . . . . . . . . . . . . .
11/4 W x 31/2 (to mounting hole centers) x 21/
Capillary length . . . . . . . . . . . .
Lead length . . . . . . . . . . . . . . . . . . . . .
Agency . . . . . . . . . . . . . . . . . . . . . . . . .
U.L. recognized and C.S.A. certified
See end of this section for parts and accessories
Calibrated temperature dial.
Model Switch Resistive (Non-Inductive) (Full Load) (Locked Rotor)
Number Range Differential Action 120 VAC 240 VAC 277 VAC 120 VAC 240 VAC 120 VAC 240
0 to 50 F 6 F Open on Rise 25.0A 25.0A 22.0A 1 0.0A 6.0A 60.0A 36.0A