New banner T186EQ, 33420, ez-beam sensor, quick disconn


10 to 30V dc (10% max. ripple) Opposed Emitters:25 mA (exclusive of load)
Opposed Receivers:20 mA (exclusive of load)
Polarized Retroreflective:30 mA (exclusive of load)
Non-polarized Retroreflective:25 mA (exclusive of load)
Diffuse:25 mA (exclusive of load)
Fixed-field:35 mA (exclusive of load)
Fixed-field:0-25, 0-50 or 0-100 mm cutoff, depending on model
Protected against reverse polarity and transient voltages
Solid-state complementary (SPDT) dc switch:NPN (current sinking) or PNP (current sourcing), depending on model. The dark operate (DO) output may be wired as a normally open marginal signal alarm output, depending upon hookup to the power supply.
150 mA max. (each) in standard hookup. When wired for alarm output, the total load may not exceed 150 mA OFF-state leakage current::less than 1 A @ 30V dc
ON-state saturation voltage:less than 1V @ 10 mA dc; less than 1.5V @ 150 mA dc
Protected against false pulse on power-up and continuous overload or short circuit of outputs
Response time is independent of signal strength. Opposed:3 milliseconds ON; 1.5 milliseconds OFF
Polarized Retroreflective, Non-polarized Retroreflective, Diffuse and Fixed-field:3 milliseconds ON/OFF
100 milliseconds; outputs do not conduct during this time.
Repeatability is independent of signal strength. Opposed:375 microseconds
Polarized Retroreflective, Non-polarized Retroreflective, Diffuse and Fixed-field:750 microseconds
Green ON steady:power to sensor is ONGreen flashing:output is overloadedYellow ON steady:light-operate (LO) output is energizedYellow flashing:marginal excess gain (1-1.5x) in light condition, LO output is energized
2 m or 9 m attached cable, or 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately.
All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation)