EXCLUSIVE FORUM FOR MACHINE DISMANTLERS AND REPAIR PEOPLE   >   Gary Indiana   >   Tekmar 650 snow melt control w/pulse width modulation

Tekmar 650 snow melt control w/pulse width modulation


I bought this for a Car Wash renovation project and wound up not needing it. It is Brand New in Box with all sensors, wiring diagrams, manuals, etc
Information available here to see if it will work for your application: http:// /prod/650.shtml
Control Description The Snow Melting Control 650 is a microprocessor-based manual start / stop control that maintains a set temperature in a snow melting slab. The 650 uses pulse width modulation (PWM) to operate an on / off injection valve, pump, boiler or contactor for electric cables. Other 650 features include Slab Outdoor Reset, Warm Weather Cut Off, Cold Weather Cut Off, Snow Melting Setpoint and Snow Idling Setpoint. The control also has a built-in timer for timed melting events.
D 650, A 650, D 001, D 070, D 079
Microprocessor PI control; This is not a safety (limit) control
1.3 lb. (600 g), Enclosure C, white PVC plastic
4-3/4" H x 2-7/8" W x 7/8" D (120 x 74 x 22 mm)
Indoor use only, -20 to 120 F (-30 to 50 C), < 90% RH non-condensing
Class 2, 24 V (ac) 10% 50/60 Hz 2 VA or 32 V (dc) 20% 0.04 A
240 V (ac) 10 A 1/3 hp, pilot duty 240 VA 2 A
NTC thermistor, 10 k @ 77 F (25 C 0.2 C) =3892
Outdoor Sensor 070 and Slab Sensor 072
0:30 to 19:50 hours to 'Infinite'
Off, 23 to 34 F (Off, -5 to 1vC)
Off, -22 to 23 F (Off, -30 to -5 C)



Tekmar 650 snow melt control w/pulse width modulation